Datasheet

https://www.phoenixcontact.com/us/produkte/2865405
Nov 14, 20134/7
Output signal conditioner-MACX MCR-EX-SL-IDSI-I-2865405
Technical data
Safety characteristic data
Probability of a hazardous failure per hour (PFH
D
)
2,79 x 10
-8
Diagnostic coverage (DC)
(DC
S
= 0%, DC
D
= 0%)
Safety data
Max. output voltage U
o
27.7 V
Max. output current I
o
92 mA
Max. output power P
o
633 mW
Gas group
IIC
Max. external inductivity L
o
2 mH
Max. external capacity C
o
85 nF
Safety-related maximum voltage U
m
253 V AC (125 V DC)
classifications
eCl@ss
eCl@ss 4.0
27210121
eCl@ss 4.1
27210121
eCl@ss 5.0
27210121
eCl@ss 5.1
27210121
eCl@ss 6.0
27210121
eCl@ss 7.0
27210121
eCl@ss 8.0
27210121
ETIM
ETIM 2.0
EC001431
ETIM 3.0
EC001596
ETIM 4.0
EC001596
ETIM 5.0
EC001596
UNSPSC
UNSPSC 6.01
30211506
UNSPSC 7.0901
39121008
UNSPSC 11
39121008
UNSPSC 12.01
39121008
UNSPSC 13.2
39121008
approvals
IECEx / UL Listed / cUL Listed / ATEX / cULus Listed / UL Listed / cUL Listed / GL / Functional Safety / cULus Listed /
Approval details