Datasheet

https://www.phoenixcontact.com/us/produkte/2865366
Nov 13, 20133/5
Repeater power supply-MACX MCR-EX-SL-RPSSI-2I-2865366
Technical data
Connection data
Conductor cross section solid max.
2.5 mm²
Conductor cross section stranded min.
0.2 mm²
Conductor cross section stranded max.
2.5 mm²
Conductor cross section AWG/kcmil min.
24
Conductor cross section AWG/kcmil max
14
Stripping length
7 mm
Screw thread
M3
Connection method
Screw connection
Tightening torque, min
0.5 Nm
Tightening torque max
0.6 Nm
General
Maximum transmission error
< 0.1 % (of final value)
Transmission error, typical
< 0.05 % (of final value)
Maximum temperature coefficient
< 0.01 %/K
Step response (10-90%)
< 1.3 ms (for 4 mA ... 20 mA step)
Status display
Green LED (PWR supply voltage)
Inflammability class according to UL 94
V0
Housing material
PA 66-FR
Color
green
Name
Input/output/power supply
Electrical isolation
300 V
rms
(Rated insulation voltage (surge voltage category II;
pollution degree 2, safe isolation as per EN 61010-1))
Electrical isolation
2.5 kV (50 Hz, 1 min., test voltage)
Name
Input/output
Electrical isolation
375 V (Peak value in accordance with EN 60079-11)
Name
Input/power supply
Electrical isolation
375 V (Peak value in accordance with EN 60079-11)
Name
Output 1/output 2
Electrical isolation
1.5 kV AC (50 Hz, 1 min., test voltage)
Conformance
CE-compliant, additionally EN 61326
ATEX
 II (1) G [Ex ia Ga] IIC/IIB
ATEX
 II (1) D [Ex ia Da] IIIC
ATEX
 II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
IECEx
[Ex ia Ga] IIC/IIB
IECEx
[Ex ia Da] IIIC
IECEx
Ex nA [ia Ga] IIC/IIB T4 Gc
Functional safety (SIL)
SIL 2 according to EN 61508
Data communication (bypass)
HART function
Yes
Protocols supported
HART