Datasheet
https://www.phoenixcontact.com/us/produkte/2865340
Nov 14, 20134/8
Power/input isolating amplifier-MACX MCR-EX-SL-RPSSI-
I-2865340
Technical data
Safety characteristic data
Probability of a hazardous failure on demand (PFD
AVG
)
2.19 x 10
-4
(1 year)
Probability of a hazardous failure on demand (PFD
AVG
)
8.76 x 10
-4
( years)
Probability of a hazardous failure on demand (PFD
AVG
)
1.1 x 10
-3
(5 years)
Diagnostic coverage (DC)
(DC
S
= 0%, DC
D
= 0%)
Integrity requirement
IEC 61508 - High demand
Equipment type
Type A
Safety Integrity Level (SIL)
Up to 2
Safe Failure Fraction (SFF)
90.7 %
λ
SU
4.867 x 10
-7
(486.7 FIT)
λ
SD
0
λ
DU
5 x 10
-8
(50 FIT)
λ
DD
0
Probability of a hazardous failure per hour (PFH
D
)
4,99 x 10
-8
Diagnostic coverage (DC)
(DC
S
= 0%, DC
D
= 0%)
Safety data
Max. output voltage U
o
25.2 V
Max. output current I
o
93 mA
Max. output power P
o
587 mW
Gas group
IIC
Max. external inductivity L
o
2 mH
Max. external capacity C
o
107 nF
Safety-related maximum voltage U
m
253 V AC (125 V DC)
Input voltage U
i
≤ 30 V
Input current I
i
≤ 130 mA
Input power P
i
(negligible)
Max. internal capacitance C
i
(negligible)
EMC data
Name
Electromagnetic RF field
Standards/regulations
EN 61000-4-3
Typical deviation from the measuring range final value
1 %
Name
Fast transients (burst)
Standards/regulations
EN 61000-4-4
Typical deviation from the measuring range final value
1 %
Name
Conducted interferences
Standards/regulations
EN 61000-4-6
Typical deviation from the measuring range final value
1 %