User manual
3. Over load and short circuit protections
Alarm/protection Signals Trouble shooting
Over load alarm Load Level Led flash, buzzer beep Check the AC
wiring, reduce the
load
Over load or short
circuit protection
Status Led red, Load Level Led off
When entering protection “status”, turn off the inverter, then turn on again to reconnect the AC
output.
4. Over temperature protection
Alarm/protection Signals Interior
Temperature
Trouble shooting
Over temperature
protection
Status LED red
flashing
quickly twice every 1.6
seconds
70±5 ℃ Improve the ventilation,
or reduce the ambient
temperature
When the inverter interior temperature returns below 45±5 , the inverter resumes normal℃
operation.
WARNING: Do not open or disassemble the Inverter. Attempting to service the unit by
yourself may result in risk of electrical shock or fire hazard.
26