Datasheet
CXup series (10 – 40 A)
Solar Charge Controllers with LC Display and USB port
Datasheet_CXup series_2/2_e_2016-04-12_Subject to change without notice
Type CXup 10 CXup 20 CXup 40
System voltage 12/24 V auto recognition
Max. charge/load current 10 A 20 A 40 A
Float charge (lead acid battery) 13.8/27.6 V (25 °C)
Main charge (lead acid battery) 14.4/28.8 V (25 °C), 30 min. (daily)
Boost charge (lead acid battery) 14.4/28.8 V (25 °C), 2 h
Activation: battery voltage < 12.3/24.6 V
Equalization charge (lead acid battery) 14.8/29.6 V (25 °C), 2 h
Activation: battery voltage < 12.1/24.2 V
Charge voltage for LiFePO4 battery 14.0/28.0 V (temperature limit: -20 to +60 °C)
Deep discharge protection: Lead acid battery: 11.5-12.0 V / 23.0-24.0 V by SOC; 11.0 -11.5 V / 22.0 - 23.0 V by voltage
Cut-off voltage LiFePO4 battery: 11.5/23.0 V by voltage
Reconnect level 12.8/25.6 V for lead acid battery; 12.2/24.4 V for LiFePO4 battery
Overvoltage protection 15.5/31.0 V
Undervoltage protection 10.5/21.0 V
Max. panel voltage 30 V in 12 V system
(Surge protection by varistor) 50 V in 24 V system
Temperature compensation −25 mV*K at 12 V
(Charge voltage) −50 mV*K at 24 V
Idle self-consumption < 4 mA
Grounding Positive grounded
Ambient temperature −40 to +60 °C
Max. altitude 4,000 m above sea level
Battery type Lead acid (GEL, AGM, flooded), LiFePO4
Data logger 2 years
USB charging port 5.0 V; 1,500 mA
External temperature sensor Yes
Wire cross section Up to 16 mm
2
Dimensions (W x H x D) 101 x 103 x 32 mm
Weight 168 g 179 g
Type of protection IP20
www.phocos.com
Phocos AG
Magirus-Deutz-Str. 12
89077 Ulm, Germany
Phone +49 731 9380688-0
Fax +49 731 9380688-50