User manual

Max. panel voltage 30 V in 12 V system, 50 V in 24 V system
Max. battery voltage 50 V
Temperature
compensation
(Charge voltage for lead
acid)
−25 mV/K at 12 V
−50 mV/K at 24 V
Self consumption (idle) < 4 mA
Grounding Positive grounded
Ambient temperature −40 to +60 °C
Max. altitude 4,000 m above sea level
Battery type Lead acid (GEL, AGM, flooded), LiFePO4
USB connector 5.0 V; 1500 mA
Dimensions (WxHxD) 101 x 103 x 32 mm
Weight 205 g 213 g
Max. wire size Max. 16 mm²
Type of protection IP20
**: Please see graph of SOA (Safe Operating Area)
37