Daim Ntawv Qhia Tus Neeg Siv

www.phocos.com 3 | P a g e
Any-Grid Master Battery
5. Ensure the battery modules are wired as outlined in the ZRGP battery manual. Turn on the batteries with
their ON/OFF switch:
6. Ensure the ON/OFF load power button of the Any-Grid(s) is in the ON position (depressed), but no loads are
connected:
The Any-Grid(s) should now be running, the display(s) on.
7. Apply the following setting on the Any-Grid to which the ZRGP battery bank is connected with the
communication cable. This setting refers to the Any-Grid manual, chapter Operation Device Operation
Settings Settings menus.
Battery type
Menu 05: User-defined battery (“USE”)
8. Once the setting has been applied, exit the settings menu by pressing to return to the main view.
9. Activate the circuit breakers or insert the fuses to energize the various inputs and outputs on the Any-Grid in
the following order (skip any that are not connected):
a) AC input
b) PV input
c) AC output
10. If you are using more than one Any-Grid, this procedure ensures that the unit to which the ZRGP battery is