User manual

Safety Features
PV terminals Battery terminals Load terminals
Reverse polarity Protected
Warning:
Red LED on
Protected (1)
Short circuit (2) Protected Protected (3) Switches off immediately
Overcurrent --- ---
Switches off with a delay
(4)
Reverse current Protected --- ---
Overvoltage Max. 30 V Max. 30 V Switches off above 15.5 V
Undervoltage --- --- Switches off
Over-
temperature
Reduces the charging current if over temperature occurs and
switches off the load if the temperature reaches high level.
34