UART
A UART port is provided for AT command and data interaction and optionally for application
specific control.
Battery Monitor
The battery monitor is internal analog input scaled such that the DC value of the power input
pin to the Dagger-QG system is measured.
Watchdog
Qualcomm chipset supports internal software and hardware Watchdog.
Motion Detect
This function will work with firmware power down options to keep the Dagger-QG in a very
low power down state until motion is detected. Upon wakening, a report can then be
generated.
2.2 Basic RF Performance
Requirements
Remark
CTIA
TRP free space
CTIA
TIS free space
Radio Frequency
BLE5.0
ISM 2.4GHz
Follow Chipset
Follow Chipset
4G LTE Cat.M1
Band 2/4/5/12/13/25/26
Follow 3gpp TS 36.521 Ch.7
Follow 3gpp TS 36.521 Ch.6
GPS
L1-band (1.57542GHz)
2.3 Certification and Safety
Items
Requirement
Drop Design
0.8meter 6 direction standard drop test
Temperature Range
-20 to 60°C Operation
-40 to +85°C Storage
Humidity:
20% to 90% Operation
10% to 95% Storage
FCC Certification
FCC Part 15/22/24/27/90
IC Certification
RSS-130/132/133/139/247
ESD Requirement
8KV non-Conductive