6.0 TEST AND INSPECTION PLAN
The test plan is derived from the Product Test Reference of XENIUM DB-W@P.
6.1 User Interface Test
Use the Test SIM Card « SP »/ Production to test the transceivers as follows :
♦ On/Off button
♦ LCD Backlight
♦ Keyboard Test
♦ Buzzer Test
♦ Vibrator Test
♦ Audio Test
♦ Antenna Test (levels 5 & 10)
♦ LCD
♦ LED Test (On/Off)
♦ IMEI
♦ Tester Status/Eeprom Status
With a fast Charger connected with the PRODUCT’s bottom connector , check the full scrolling from
one mode to the next when charging IGN (Ignition) – Battery.
6.2 RF Test
The radio test must be performed with a Digital Radio Test Set connected to the RF connector with the
specific RF cable.