User Guide
Table Of Contents
- Contents
- Introduction
- General description
- Intended use
- Important safety information
- Cleaning and disinfecting
- Using the breast pump
- Feeding breast milk with the bottle
- Compatibility
- Ordering accessories
- Recycling
- Battery removal instructions
- Warranty and support
- Troubleshooting
- Supplemental information
- Storage conditions
- Electromagnetic fields (EMF)
- Technical information
- Explanation of symbols
- Sommaire
- Introduction
- Description générale
- Usage prévu
- Informations de sécurité importantes
- Avant la première utilisation
- Nettoyage et désinfection
- Utilisation du tire-lait
- Nourrir votre bébé avec un biberon de lait maternel
- Compatibilité
- Commande d'accessoires
- Recyclage
- Instructions de retrait de la batterie
- Garantie et assistance
- Dépannage
- Informations supplémentaires
- Conditions de stockage
- Champs électromagnétiques (CEM)
- Informations techniques
- Explication des symboles
26
English
Technical information
Single electric breast pump Double electric breast pump
Vacuum level
Stimulation: -60 to -200 mbar (-45 to -150 mmHg)
Expression: -60 to -360 mbar (-45 to -270 mmHg)
Adjustable in steps of 20 mbar
Intermittent vacuum
Cycle speed
53-120 cycles/min.
Motor unit rated input 5 V d.c. / 1.1 A 5 V d.c. / 1.8 A
Mains adapter rated input
External mains adapter 100-240 V a.c.
50/60Hz
400 mA
Mains adapter rated output 5 V d.c. / 1.1 A 5 V d.c. / 1.8 A
Adapter type number
S009AHz050yyyy The letters "yyyy" represent the output current from 0100
(1000mA) to 0180 (1800mA), increments in steps of 100mA. The letter "z"
denotes type of plug, it can be: U, V, B, S, C, A, D, K, T, I, E, F.
Battery
Rechargeable battery: 3.6V2600mAh (non-replaceable)
Operating conditions
Temperature: 5°C to 40°C (41°F to 104°F)
Relative humidity: 15 to 90% (non-condensing)
Storage and transportation
conditions
Temperature: -25°C to 70°C (-13°F to 158°F)
Relative humidity: up to 90% (non-condensing)
For optimal performance of the built-in rechargeable battery, it is
recommended to store the device at room temperature.
Operating pressure 700-1060hPa (<3000m altitude)
Net weight 230g 310g
External dimensions
Motor unit: 145 mm x 95 mm x 45mm (LxWxH)
Device classification
IEC 60335-1: System: Class II; motor unit: Class III Construction
Materials
ABS, silicone (motor unit)
Polypropylene, silicone (other parts)
Service life 500 hours
Mode of operation Continuous operation Non-continuous operation
55min on, 180min off at 22°C
(72°F) (duty cycle 23%)
20min on, 90min off at 40°C
(104°F) (duty cycle 18%)
Ingress protection IP22 (motor unit), IP20 (adapter)