Operation Manual
Rated input 16 W
Protection against electric shock Class II, double insulated
Protections rating IP 30 (EN 60529)
Operating conditions Temperature:+15 °C to 35 °C
Storage conditions temperature -25 °C to 70 °C
Relative humidity
Less than 90% (non condensing)
Operating pressure 700 - 1060 hPa
Altitude Max. 3000 m
Emitted wavelengths 565 - 1400 nm, depending on attachment
Optical exposure 2.5 - 6.5 J/cm², depending on chosen setting and
attachment
Maximum optical energy 23 J
Pulse duration
<2.0 ms
Repetition time 1-3.5 s, depending on chosen setting
Optical homogeneity
Max. +/- 20% deviation from average optical
exposure in treatment area
Troubleshooting
This chapter summarizes the most common problems you could encounter
with the device. If you are unable to solve the problem with the information
below, visit www.philips.com/support for a list of frequently asked
questions or contact the Consumer Care Center in your country.
Problem Possible cause Solution
The device suddenly
switches off.
The rechargeable batteries
are empty
Charge the device. See Chapter
Charging.
The device/adapter
becomes warm during
charging
This is normal. No action required.
I cannot use the device
from the mains.
Due to safety reasons it is not
possible to use the device
from the mains.
Philips Lumea can only be used without
cord.
The 'ready to flash light'
doesn't light up when I
place the attachment on
my skin, but the cooling fan
works.
The device and attachment
are not in proper contact with
the skin.
Adjust the pressure or angle of the
device on the skin.
26
English