Technical data
122
Protective Devices
Accessories for PLHT, PLHT-V
Technical Data
Electrical
Operational voltage range
Z-LHASA/230: 110-415 V~
Z-LHASA/24: 12-60 V~
Operational frequency 50-60 Hz
Max. current consumption at point of switching on at U
n
Z-LHASA/230: 2 A
Z-LHASA/24: 18 A
Mechanical
Frame size 45 mm
Device height 90 mm
Device width 27 mm
Mounting quick fastening on
DIN rail IEC/EN 60715
Degree of protection, built-in IP40
Upper and lower terminals lift terminals
Connection diagram
1
2
Shunt Trip Release Z-LHASA
• Can be mounted subsequently
• Contact position indicator red - green
• Marking labels can be fitted
• Wide operational voltage range
• Sufficient power of extra low voltage source must be ensured
Z-LHASA/24: min. 90 VA
Dimensions (mm)
Technical Data
Electrical
Rated operational current (250 V~) 6A/AC13
Minimum operational voltage 24V each line
Rated thermal current 8 A
Rated insulation voltage 440 V~
Maximum back-up fuse 6 A gL
or CLS6-4/./B-HS
Contacts 1NO+1NC
Utilisation category AC13 6A/250VAC
2A/440VAC
Utilisation category DC13 4A/60VDC
2A/110VDC
0.5A/230VDC
Mechanical
Frame size 45 mm
Device height 90 mm
Device width 9 mm
Mounting mounted onto protective
devices
Degree of protection, built-in IP40
Upper and lower terminals lift terminals
Terminal capacity 1 x 1mm
2
to 2 x 2.5mm
2
Connection diagram
21
13
22
14
Auxiliary Switch Z-LHK
• Auxiliary switch according to IEC 947-5-1
• Can be mounted subsequently
Dimensions (mm)