Specifications
Fault finding and repair tips
GB 16 EM1A5.
Entering
• Via a standard RC-handset by entering the code
'062596' followed by the 'OSD' button [i+].
• Via ComPair.
• By the 'ALIGN' button on the DST while the set is in the
normal operation mode.
The following screen will be shown, with 'SAM' at the upper
right side for recognition.
Figure 5-2
Explanation
The Service Alignment Mode menu will now appear on the
screen. The following information is displayed:
1. Operation hours timer (hexadecimal).
2. Software identification of the main micro controller
(AAABBB-X.Y).
• AAA is the chassis name (EM1= Painter processor,
EM2= OTC processor).
• B = Software code belonging to a certain stroke
number (see table below).
• X = (main version number).
• Y = (subversion number).
3. Error buffer (7 errors possible).
4. Option bytes (8 codes possible), summary of options are
explained below.
5. Sub menus are listed in a scroll-menu.
NORMAL RED
PICTURE BRIGHTNESS
SOUND COLOUR
FEATURES CONTRAST
INSTALL SHARPNESS
COLOUR TEMP
SAM
SAM
SAM
SAM
SAM
NPRG
WSSB
SYSTEM
OB1
OB2
HRS: 0003 SWID: EM11A1-1.0
ERR: 0 0 0 0 0 0 0
OPT: 254 100 128 0 0 0 0 0
CLEAR ERRORS
OPTIONS
AKB ON/OFF
OPC ON/OFF
VSD ON/OFF
TUNER
WHITE TONE
GEOMETRY
SOUND
TUNER
IF-PLL OFFSET
AGC
2ND
AFA
AFB
SAM Menu
MENU
MENU
MENU
MENU
MENU
MENU
CL 06532130_011.eps
021000
1
5
2 3 4
SOUND
NIC-FMAM
2CS-FM
PS-FM
PS-NIC-BGDK
PS-NIC-I
SAM
VER-SLOPE
SAM
Country Strokenumber Software
Singapore /69 2A1
Thailand
Malaysia
Indonesia
Middle East /56 2A2
China /93 1A1
Hong Kong /57 2A1
Australia /79
New Zealand