Compatibility Chart
15 InstantFit Ballast Compatibility Guide
Emergency Ballasts
Emergency Ballasts
(contact the emergency ballast
manufacturer for wiring diagrams)
7 W 1050 lm
(2 ft.)
8.5 W 1200 lm
(3 ft.)
13W 2100 lm
(U-Bent)
3
10 W 1600 lm
(4 ft.)
13 W 2100 lm
(4 ft.)
14 W 2100 lm
(4 ft.)
14 W 2100 lm
(4 ft. Glass) T5 HO T5 HE
469270, 469288
469296, 469304
469429, 469445
469437, 541813
541821, 541839
541847
469320, 469338
469346, 469353
469452, 469478
469460, 539858
539874, 539882
539866
469379, 469387
469395, 469403
469411, 470625
541854, 541862
541870, 541888
468264, 468272
468280, 468298
468694, 469569
469577, 469585
469593, 473966
473974, 473982
473990, 474007
473926, 473934
473942, 473958
468306, 468314
468322, 468330
469061, 469619
469627, 469635
468652, 468660
468678, 468686
470096, 470104
470112, 470120
467126, 467134
467142, 467159
476499, 476507
476515, 476523
Manufacturer Ballast Model
# of lamps
in emergency Performance
1
Performance
1
Performance
1
Performance
1
Performance
1
Performance
1
Performance
1
Performance
1
Performance
1
Philips Bodine B50* 1 System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied
Philips Bodine B50CT 1 System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied
Philips Bodine B50-CAN 1 System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied
Philips Bodine B30HV 1 System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied
Philips Bodine PEL12 1 System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied
Philips Bodine LP600 1 System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied
Philips Bodine LP600STU 1 Not Recommended Not Recommended System Certied System Certied System Certied System Certied System Certied System Certied System Certied
Philips Chloride DEB-6LP 1 System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied
Iota Engineering I-320 1 or 2 System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied
Iota Engineering I-1605 1 or 2 System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied
Iota Engineering I-162 2 System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied
Iota Engineering IS L- 5 4 1 or 2 System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied
Iota Engineering IS L- 5 4 0 1 or 2 System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied
Fulham Co., Inc FH7-UNV-500L 1 System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied
Fulham Co., Inc FH11-UNV-750L-xx 1 System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied
Fulham Co., Inc FH12-UNV-1400K-xx 1 System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied System Certied
1. System performance “System Certied” means Philips InstantFit LED T8 lamps and ballast have been evaluated by the lamp and ballast manufacturer. * Must use 12 NC: 913702456401.
System performance “Certied” means Philips InstantFit LED T8 lamps and ballast have been evaluated by the lamp manufacturer only.
System performance “blank” eld means consult factory.