Specifications
Mechanical Instructions
EN 9TPS1.3A LA 4.
4.3.5 Power Supply Board
1. Refer to next figure.
2. Unplug all the connectors [1].
3. Remove the fixation screws [2]
4. Remove the board.
Figure 4-7 Power supply board
4.3.6 Scaler Board (SB)
Caution: it is absolutely mandatory to remount all different
screws at their original position during re-assembly. Failure to
do so may result in damaging the SB.
Removing the SB
1. See the figure ”SB removal”.
2. Unplug all of the cables [1].
3. Removed the parker screws [2].
Figure 4-8 SB removal
4.4 Set Re-assembly
To re-assemble the whole set, execute all processes in reverse
order.
Notes:
• While re-assembling, make sure that all cables are placed
and connected in their original position. See figure "Cable
dressing".
• Pay special attention not to damage the EMC foams at the
SB shields. Make sure, that EMC foams are put correctly
on their places.
I_17610_009.eps
280308
12
12
11
I_17610_011.eps
280308
11
12
12