Specifications

Mechanical Instructions
EN 9TPS1.3A LA 4.
4.3.5 Power Supply Board
1. Refer to next figure.
2. Unplug all the connectors [1].
3. Remove the fixation screws [2]
4. Remove the board.
Figure 4-7 Power supply board
4.3.6 Scaler Board (SB)
Caution: it is absolutely mandatory to remount all different
screws at their original position during re-assembly. Failure to
do so may result in damaging the SB.
Removing the SB
1. See the figure ”SB removal”.
2. Unplug all of the cables [1].
3. Removed the parker screws [2].
Figure 4-8 SB removal
4.4 Set Re-assembly
To re-assemble the whole set, execute all processes in reverse
order.
Notes:
While re-assembling, make sure that all cables are placed
and connected in their original position. See figure "Cable
dressing".
Pay special attention not to damage the EMC foams at the
SB shields. Make sure, that EMC foams are put correctly
on their places.
I_17610_009.eps
280308
12
12
11
I_17610_011.eps
280308
11
12
12