Specifications
Alignments
EN 68 SDI PDP 2K68.
Figure 8-8 Location of the test points for the supply voltages - X-main - 42” HD w1
8.1.5 Adjustment Power Supply Voltages 50" HD w1
Table 8-3 Adjustment voltage level overview (also refer to the sticker on the rear side of the panel)
TG}GjGwG
Vs (200V) – F4003 Ve (110V) – F4005
Vcc (15V) – F4001 5.5V (5.5V) – F4004
G_16380_505.eps
160606
No Output voltage (V) Voltage Setting (Normal Load) Output Voltage Range
1 VS 202 V ± 1 % 190 V ~ 210 V
2 VA 65 V ± 1.5 % 55 V ~ 75 V
3 VE 115 V ± 1.5 % 110 V ~ 130 V
4 VSET 190 V ± 1.5 % 170 V ~ 200 V
5 VSCAN -190 V ± 1.5 % -210 V ~ -180 V
6 VSB 5 V ± 5 % Fixed
7 VG 15 V ± 5 % Fixed
8 D5VL 5.2 V ± 5 % Fixed
9 D3V3 3.3 V ± 5 % Fixed
Check voltage label on the PDP for correct values.