Technical data
26
Go to cover page
200WP7 LCD
DDC Instructions
Step 6: Save DDC data
Sometimes, you may need to save DDC data as a text file for using
in other IC chip. To save DDC data, follow the steps below:
1. Click (Save) icon (or click "file"-> "save as") from the tool bar
And give a file name as shown in Fig. 32.
The file type is EDID46 file (*.ddc) which can be open in WordPad.
By using WordPad, the texts of DDC data & table (128 bytes, hex
code) can be modified. If DDC TEXTS & HEX Table are completely
correct, it can be saved as .ddc flie to re-load it into DDC IC for DDC
Data application.
2. Click .Save
Step 7: Exit DDC program
Pull down the File menu and select Exit as shown in Fig. 33.
Step 5: Write DDC data
1. Configuration should be as Fig. 31. And press OK.
3. Click (Write EDID) icon from the tool bar to write DDC data.
Fig. 31
Fig. 33
Fig. 32
2. Access Factory Mode
[PushAUTO" "&OK" "buttonsatthesametimeand
holdit]+[Press power " " button untill comes out "Windows
screen"] => then release all button
- Turn off monitor.
-
Edid45.1
200P7
BOMCode
Panel Supplier CODE
AUO 1
CPT 2
LPL(LG)3
QDI4
CMO 5
B Z 3A0601 000001
SERIALNO
YEAR/WEEK
SERVICE VERSIONCHANGE CODE
BOMCODE(BILL OF MATERIAL)CODE
SITE CODE(PRODUCTIONCENTER)
BZCODE(AR-CZECH REPUBLIC
VN-HUNGARY(SZR),BZ-SUZHOU
DS-DONGGUAN)