Technical data

19
Go to cover page
200WP7 LCD
TO access factorymode
1. Turn off monitor(do not turn off PC)
2. Press AUTO , OK and thepower simultaneously on the frond control
panel, then press OK waittill the OSD menu comeon the screen of
monitor.
3.If OSD menu disappears on the screen ofmonitor. press OK
again(anytime), then the OSD menu comes on the screen again.
4. Usetoselect OSD menu.
5. Usetoaccess/confirm the selection.
Move thecursor to yellow area (see red circleo
nFig.1)
press OK button to access to factorymode.(see Fig.2)
Fig.1
Fig.2
Fig.3
Fig.7
Fig.4
Fig.6
O-CAL
PC mode WHITE-D adjustment (B)
1 Apply 1280X1024/60Hz mode with 64gray level pattern as Fig
3. Set maincontrolsbrightness control at 100% and contrast to
50% on User mode. Set color setting at original panel color on
User mode. Move cursor to "Auto-SUB" item on factory mode,
press "OK" key to acti vate thisfunction.
2.6Switch light probe to Viewing position.
2.7 Move the Lens barrel forward or backward to get clear image
as shown in Fig. 7
2.8Switch light probe to Measuring position. It should be able to
indicate colour value on the CA-110.
2. Apply a 1280x1024/60Hz signal with white pattern.Set
brightness control at 100% and contrast control at 50%. Adjust
the R.G.B gain to reach special color temperature on center of screen.
2.1Aim the probe CA-A30 at the center of screen as Fig. 4
2.2 Remove the lens protective cover of probe CA-A30.
2.3 Set Measuring/viewing selector to Measuring position for reset
analyzer. (Zero calibration) as Fig. 5
2.4 Turn on the colour analyzer (CA-110).
2.5 Press 0-CAL button to start reset analyzer. See Fig. 6
Display Adjustment