Specifications

Design-in guide Philips Fortimo LED Line High Voltage System 47
Environmental reliability tests
Test name
Reference
Test conditions
Low-temperature storage
IEC/EN 60068-2-1
Tamb -40 °C
High-heat storage
IEC/EN 60068-2-2
Tamb +100 °C
Non-operational thermal shock
IEC/EN 60068-2-14
Tamb -40 …+125 °C, Xfer 20s, Dwell 28 min
Operational life continuous operation
IEC/EN 60068-2-2
Tamb +35 °C
Operational life power cycle
IEC/EN 60068-2-2
Tamb +35 °C; on/off 60/60 min
Change temperature storage
IEC/EN 60068-2-14
Tamb -40 …+100 °C, Xfer 30 min, Dwell 30 min
Change temperature operational
IEC/EN 60068-2-14
Tamb -40 …+85 °C, cycle 60 min, Dwell 20 min
Damp heat operation
IEC/EN 60068-2-78
Tamb +60 °C, RH 93%, on/off 30/30 min
Mechanical reliability tests
Test name
Reference
Test conditions
Random mechanical vibration (non-
operational)
JESD22-B103
Acc 6 G, f 10-200 Hz, time 10 mins
Mechanical shock (non-operational)
JESD22-B103
Acc 1500 G, pulse 0.5 ms, shocks 6
Cautions on use during storage, transportation and operation
When storing this product for a long time (more than one week)
Store in a dark place. Do not expose to sunlight.
For Fortimo LED Line: maintain temperature between -40 ~ +85 °C, and RH 5
85 %.
For LED Line Cover 2ft soft-diffuse: maintain temperature between -40 ~ +75
°C, and RH 5 85 %.
During transportation and storage for a short time
Maintain temperature below 100 °C at normal humidity.