Specifications

Design-in guide Philips Fortimo LED Line High Voltage System 27
How to measure the temperature of the LED Line
Tc point to measure the LED Line 1ft 3R temperature
Tc point to measure the LED Line 2ft 1R temperature
The Tc values are specified at the Tc point, which is indicated on the LED
Line. The temperature can be measured via thermocouples that are firmly
glued to the upper surface of the LED Line.
For LED Line 1R and 2R also the onboard NTC can be used for
measurements during development. For all measurements the
temperature must be stable before any reliable data can be obtained
(between 0.5 and 3 hours).
Tc point to measure the LED Line 2ft 2R temperature
Red circle indicates where to place the NTC on the board
Red circle indicates where to place the NTC on the board