Technical data
30
Magnavox LCD TV
Go to cover page
DDC INSTRUCTIONS
Re-programming DDC IC
Step 1: After initialize alignment box, connecting all cables and
box as shown in Fig. 10
Fig.11
Step 2: Read DDC data from monitor
1. Click icon asshown in Fig.11fromthetoolbarto bring up
the Channels "Configuration Setup" windows asshown in Fig. 12.
Step 3: Modify DDC data (verify EDID version, week, year)
1. Click (new function)icon fromthetoolbar, b r i ng up
Step 1 of9asshown in Fig.14.
EDID45 DDC application provides the function selecti
on and
textchange (select & fill out) fromStep1to Step 9.
Step 4: Modify DDC data (Monitor Serial No.)
Next1. Click , bring up Fig. 15.
2. Click , bring up Fig. 16.Next
3. Click OK button to confirm your selection.
4. Click icon (ReadEDID function)to read DDC EDID data from
monitor. The EDID codes will display on screenasshown in Fig
.13.
Fig.15
Fig.16
2. Select the DDC2Bi asthecommunication channel.
As shown in Fig. 12.
Fig.10
1=Power connector
2=D-SUB connector
PC
To printer p
ort (L
TP1)
Printer
Port
To
Monitor
To PC
1
2
----->
----->
Fig.12
To PCVideo port (D-sub)
Fig.13
Fig.14
Don't close this screen. --->