Technical data
Display adjustment
23
Magnavox LCD TV
Go to cover page
Fig. 1
Fig.7
Clear ima ge
Measurement/viewing selector
Display adjustment
Access factory.Mode
how toget intofactorymode menu
Step 1:Selectthesource "PC" and then turn off LCD-TV.
Step 2 :[Push"power"button and then push the "VOL- " and "VOL+"
buttons at the same time immediately and hold it] about fiveseconds
then release all buttons.
Press "menu"button and br
ing up factorymode indicationasshownin
Fig.1
MAIN CONTROLS
SMART PICTURE
AUDIO BRIGHTNESS
FEATURES CONTRAST
INSTALL AUTO ADJUST
MANUAL ADJUST
1024X768@60HZ
PICTURE
1024X768@60HZ
F1/FL1 NAFTA V1.01.05 041208 LG15XGA
Use the CHNNEL- and CHNNEL+ to selectthe "F1/FL1 NAFTA V1.01.
05 041208 LG15XGA" and then press the "VOL +" button
PC mode WHITE-D adjustment (B)
1Apply 1024X768/60Hzmode with5block patternasFig 3.Set
main controls brightness controlat50% and contrast to50% on
User mode.Set color setting at natural color on User mode.Move
cursor to "AUTO-color" item on factorymode, p
ress "menu" key
to activethis function, then scalerwill adjust RGB and Color
RGB automatically byitself.
Fig.2
Fig.3
2.Apply a 1024x768/60Hzsignal withwhite pattern.Set
brightness controlat50% and contrast controlat50%.Adjust the
R.G.B gain toreach special color temperature on centerof
screen.
2.1 Aim theprobe CA-A30 at the centerofscreen as F ig. 4
2.2 Removethe lens protecti
ve coverofprobe CA-A30.
2.3 Set Measuring/viewing selector toMeasuring position for reset
analyzer. (Zero calibration) as Fig. 5
2.4 Turn onthe colour analyzer (CA-110).
2.5 Press 0-CAL buttonto start reset analyzer. See Fig. 6
Cover (black)
Measurement viewing selector
O-CAL
Fig.4
Fig.6
Fig.5
2.6 Switch lightprobetoViewing position.
2.7 Movethe Lens barrel forward or backwardtoget clear imageas
showninFig. 7
2.8 Switch lightprobetoMeasuring position.Itshould beable to
indicate colourvalue onthe CA-110.