Technical data
42
150MT10P LMT
Go to cover page
Colour Adjustment
9300 K
13. Press or buttons to selectRGB.Increase/decrease value by
press or buttons until the X, Y co-ordinates as below:
x= 0.281 0.005
y= 0.311 0.005
Y>= 250 nits
6500 K
14. Setting X, Y value listed as below:
X= 0.312 0.005
Y= 0.338 0.005
Y>= 250 nits
Alignment hits: 1. R for x value , G for y value, B for Y value on the
colour analyzer.
2. If the colour analyzer has been calibrated and preset
colour temperature in it. Please switch to correct
setting in accordance with colour settings.
0
0
15. Gray scale checking
- Switch Timing/pattern generator to
Pattern: 32 gray scale
Timing: 1024 X 768 60Hz 48KHz
- Setting both Brightness and Contrast to 50 (Value).
- Check black and white scale are visible clearly across the screen.
See Fig. 1
Measurement/viewing selector
Measurement/viewing selector
cover (black)
cover (black)
Fig. 2
Fig. 3
0-CAL
4. Entering factory adjustment mode of LCD Monitor.
- To hold and buttons then power on the monitor. Press
to bring up OSD menu for confirmation.
OK AUTO OK
Note : after alignment, please reset OSD to user s mode for normal
operation. Otherwise, the monitor won t entering power saving mode
and showing full white picture all the time as no video signal supplied.
To leave factory mode by restart the monitor.
5. Adjust OSD menu to lower position of screen (i.g. adjust V-position to
value " 0 " at submenu of OSD Setting.
6. Setting Brightness and Contrast
- Adjust Brightness to value " 70" .
- Adjust Contrast to value " 50" .
7. Switch light probe to Viewing position.
8. Move the Lens barrel forward or backward to get clear image as
shown in Fig. 4
9. Switch light probe to Measuring position. It should be able to indicate
colour value on the CA-110.
10. Setting pattern to full white picture.
11. Press then select LCD TV V1.28 20011030 by button.
12. Press to bring up submenu as following windows.
OK
OK
Fig. 1
Measurement/viewing selector
Measurement/viewing selector
Fig. 4
Clear image
Factory mode
LCD TV V1.28 20011030
White Balance Adjustment
Alignment procedure
1. Turn on 150P2E LCD monitor.
2. Turn on the Timing/Pattern generator. See Fig. 1
Setting generator to provide CROSS-Hatch pattern at
Resolution : 1024 x 768
Timing : H= 48 KHz
V= 60 Hz
3. Preset LCD colour Analyzer CA-110
- Remove the lens protective cover of probe CA-A30.
- Set Measuring/viewing selector to Measuring position for reset
analyzer. (Zero calibration) as Fig. 2
- Turn on the colour analyzer (CA-110).
- Press 0-CAL button to starting reset analyzer. See Fig. 3
Fig. 1
Note: The bright scale will be saturated, if Y is too large. The dark scale
will be invisible, if Y is too small. Re-alignment or review procedure
again to correct this.
OFFSET R G B
OFFSET R G B
GAIN R G B
GAIN R G B
GAIN R G B
GAIN R G B
COLOR R G B
SUB CON
SUB CON
-
AUTO SUB
AUTO SUB
ORIGINAL PANEL COLOR
-
EXTERNAL RAM
T V
EXIT
T V SHIFT HV
OK
FACTORY ADJUST MENU