User's Manual

PHILIPS WLAN Configuration Utility & User Manual
PHILIPS COMPONENTS
Page 12
Be sure to confirm that latches at both sides are turned on correctly e.g.
half fitting, remove the board in accordance with the next paragraph 9.3
How to remove the module board and refit it once again by starting the
fitting procedure.
HOW TO REMOVE THE MODULE BOARD
1. Move both sides of Latch simultaneously in the outward direction from the
module.
2. When the lock is released, the board will tilt approximately 25° in angle to
the connector. The board must be pulled out straight and softly in the
angle direction.
CONNECTION/DISCONNECTION OF COAXIAL CONNECTORS
1. To couple the connectors, the coupling axes of both connectors are
aligned and the connectors are inserted as perpendicularly as possible. Do not
attempt to insert on an extreme angle.
2. To disconnect connectors, hook the end portion of E.FL-LP-N onto the
connector cover and pull off vertically in the direction of the connector coupling
axis. To remove the connector directly, hold the connector cover and pull off
vertically in the direction of the connector coupling axis.
WITHRAWAL OF WIRE TO BOARD CONNECTOR
Pull out the mating part (female connector) horizontally in the direction
parallel to the housing. Apply axial pull out force of 3.0 N minimum at
the speed rate of 25±3 mm/minute.
PACKING
The modules are packed in a cupboard box. The packaging fulfilled the
requirements of transportation test stipulated in UAN-D1463. The
transport of filled boxes should be done on pool pallets.