User's Manual
(6) Select Serial Port
It is to select a useable serial port as the character of pan/tilt/zoom control receiver.
It is to select a serial port between ‘ Serial #1’ and ‘ Serial #2’ with which a pan/tilt/zoom control
receiver is connected to NetServer. Serial #1 is RS232C interface and Serial #2 is RS422/RS485
interface.
(7) Serial Port Base Address
This menu identifies the base address for a video channel and a pan/tilt/zoom (P/T/Z) control
receiver. NetServer-6 can support up to six P/T/Z devices for six separate channels when Serial #2
(RS485 Half-Duplex) is enabled. The “Serial Port Base Address” identifies each P/T/Z device to
each channel. Select a channel to configure and change the “Serial Port Base Address” to
correspond with the channel number. This will allow independent operation for up to six P/T/Z
controls. In addition, all channels can be set to the same “Serial Port Base Address” for
synchronized movement.
10) Serial Port Configuration
This page is to select a communication protocol among listed ones or to set control parameters
manually for each serial port.
(1) Serial Port Selection
Administrator selects a serial port to configure. NetServer-6 has two serial ports.
Serial #1 is a RS232C interface port, and Serial #2 is a RS485/RS422 interface
port.
(2) Select Attached Device
Administrator selects a communication protocol that an attached external device
satisfies among already listed protocols. Philips has listed protocols of Philips,
Pelco (P and D), Sensormatic, Video Technical (VTP 4x), LG (GAC-PT2), Sony
(EVI-D3x), Surveyor (PT360 and TransitRCM), Sungjin (SJ3728R1), Kukjae
(KRS-3200), Serim (SRP-PT1), Mitsubishi (CIT7300), and Samsung (SRX100B).
Administrator may utilize any pan/tilt mechanism that satisfies already listed
protocols.