User's Manual

3) LED of Ethernet port
Yellow LED: This LED indicates the status of data transmission. After power is supplied, it is on
for the first 4-5 seconds and then it goes off. And it blinks continuously when a user access
NetServer and NetServer transmits data.
Green LED: This LED indicates the status of networking. After power is supplied, it is on for the
first 1-2 seconds, and then it blinks once at every one second as long as the network is connected.
4) Descriptions on DIP Switches
This is to designate video signal termination. If you want to monitor real time image through a
CCTV monitor as well as NetServer, you may connect a dome camera to Video Input connector
and a CCTV monitor to Video Output connector. In this case, you should decide which one is
terminal of video signal. NetServer is not affected if a CCTV monitor is designated as terminal.
However, a CCTV monitor is affected if the NetServer is designated as terminal. CCTV monitor
will show vague image if it is not designated as terminal.
If you connect a dome camera to Video Input and monitor real time video only through a PC,
place the first DIP switch (marked with No. 1) at upper position ON.
Phenomenon of Malfunction
1. Network Malfunction
Green LED blinks once at every 4 seconds
; Check if Ethernet cable is connected properly or the Network works.
2. Software Malfunction
Green and yellow LEDs are on, and they blink 6 times rapidly at every 10 seconds.
; This problem is to be solved with A/S program.
Contact the dealer from who you bought
NetServer-1.
After being on for a second, Green and yellow LEDs blink 6 times rapidly. Then green
LED is on and yellow LED is off.
; This problem is to be solved by re-installing firmware. Visit Philips
s Internet homepage to
download the firmware and install it on your NetServer-1.