Section I - Physical Characteristics
1.1 Ballast shall be physically interchangeable with standard electromagnetic or standard electronic ballasts, where applicable.
1.2 Ballast shall be available in a plastic/metal can or all metal can construction to meet all plenum requirements.
1.3 Ballast shall be provided with poke-in wire trap connectors color coded per ANSI C82.11.
Section II - Performance Requirements
2.1 Ballast shall be Programmed Start except for ballasts with -QS suffix, which shall be Rapid Start.
2.2 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power.
2.3 Ballast shall operate from 50/60 Hz input source of 120V through 277V with sustained variations of +/- 10% (voltage and frequency) with
no damage to the IntelliVolt ballast. RCF models shall operate from 60 Hz input source of 120V with sustained variations of +/- 10% (voltage
and frequency) with no damage to the ballast.
2.4 Ballast shall be high frequency electronic type and operate lamps at a frequency above 42 kHz to avoid interference with infrared devices
and eliminate visible flicker.
2.5 Ballast shall have a Power Factor greater than 0.98 for primary lamp.
2.6 Ballast shall have a minimum ballast factor of 1.00 for primary lamp application.
2.7 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or less in accordance with lamp manufacturer recommendations.
2.8 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp.
2.9 Ballast shall have a Class A sound rating.
2.10 Ballast shall have a minimum starting temperature of -18C (0F) for primary lamp. Ballasts for PL-H lamps shall have a minimum starting
temperature of -30C (-20F) for primary lamp.
2.11 Ballast shall provide Lamp EOL Protection Circuit.
2.12 Ballast shall tolerate sustained open circuit and short circuit output conditions without damage.
Section III - Regulatory Requirements
3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB).
3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified
where applicable.
3.3 Ballast shall be rated for use in air-handling spaces.
3.4 Ballast shall comply with ANSI C62.41 Category A for Transient protection.
3.5 Ballast shall comply with ANSI C82.11 where applicable.
3.6 Ballast shall comply with the requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18,
Non-Consumer (Class A) for EMI/RFI (conducted and radiated).
Section IV - Other
4.1 Ballast shall be manufactured in a factory certified to ISO 9002 Quality System Standards.
4.2 Ballast shall carry a five-year warranty from date of manufacture against defects in material or workmanship, including replacement, for
operation at a maximum case temperature of 75C and three-years for a maximum case temperature of 85C (90C 3year warranty for ICF1H120-
M4-XX, ICF2S42-90C-M2-XX and ICF2S70-M4-XX modesls).
4.3 Manufacturer shall have a fifteen-year history of producing electronic ballasts for the North American market.
Revised 08/15/2006
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance can vary
depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCE
O'HARE INTERNATIONAL CENTER - 10275 WEST HIGGINS ROAD
ROSEMONT, ILLINOIS 60018
TELEPHONE: (847) 390-5000 FAX: (847) 390-5109