Cut Sheet

Metal
Halide
Lamp Ballast
Catalog Number 71A6572
For 1000W M47
60 Hz CWA
Status: Active
DIMENSIONS AND DATA
1.625"
7.75"
7.15"
B
MAX.
0.25" WIDE
2 SLOTS
A
1.75"
2.75"
6.75"
6.125"
0.312" X 0.531
4 SLOTS
6.00"
4 1/4 X 6 CORE - 2 COIL UNIT
3.90"
6.00"
5.40"
4.35"4.25"
8 HOLES
CLEARED
FOR #10
THRU-BOLTS
4.40"
Capacitor: MD2409-100
A
A
T
0.81±0.03
0.75±0.03
H
D
L
SCALE3/8
SECTIONA-A
(2)0.031X0.250BLADE.
PLUSFORK(SEENOTE7)
Capacitance: 24
Dia/Oval Dim: 1.75
Height: 3.9
Temp Rating: 90°C
This ballast does not
require the use of an ignitor.
Ignitor: NA
Data is based upon tests performed by Philips Lighting Electronics N.A. in a controlled environment and is representitive of relative performance.
Actual performance can vary depending on operating conditions. Specifications are subject to change without notice.
PHILIPS LIGHTING ELECTRONICS N.A.
10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018
Tel: 800-322-2086 · Fax: 888-423-1882 · www.philips.com/advance
Customer Support/Technical Service: 800-372-3331 · OEM Support: 866-915-5886
INPUT VOLTS 120 208 240 277
CIRCUIT TYPE
POWER FACTOR (min)
REGULATION
Line Volts
Lamp Watts
LINE CURRENT (Amps)
Operating............................................................... 9.00 5.20 4.50 3.90
Open Circuit........................................................... 4.50 2.70 2.30 2.20
Starting................................................................... 7.80 4.00 3.70 3.20
UL TEMPERATURE RATINGS
Insulation Class
Coil Temperature Code D B B B
MIN. AMBIENT STARTING TEMP.
NOM. OPEN CIRCUIT VOLTAGE
INPUT VOLTAGE AT LAMP DROPOUT................................. 84 146 168 194
INPUT WATTS
RECOMMENDED FUSE (Amps)............................................. 20 15 10 10
CORE and COIL
Dimension (A)
Dimension (B)
Weight (lbs.)
Lead Lengths
CAPACITOR REQUIREMENT
Microfarads
Volts (min.)
Fault Current Withstand (amps)
60 Hz TEST PROCEDURES (Refer to Philips Lighting
Electronics N.A. TEST Procedure for HID Ballasts - Form 127
High Potential Test (Volts)
1 minute
2 seconds
Open Circuit Voltage Test (Volts)
Short-Circuit Current Test (Amps)
Secondary Current
Input Current.......................................................... 5.60- 3.20- 2.80- 2.40- -
8.60 4.80 4.30 3.60
CWA
90%
±10%
±10%
H(180°C)
1029
-20°F or -30°C
430
1080
3.05
5.00
20
12"
24.0
480
2000
2500
385-475
5.20-6.40
Wiring Diagram:
Fig. A1
LAMP
CAP
LAMP
COM COM
LINE V
LINE V
LINE V
AL
LINE V
Typical Ordering Information
(please call Philips Lighting Electronics N.A. for suffix availability)
Order Suffix Description
001 STANDARD IC PACK - OIL CAP - FLAG TERMINALS
Revised: 03/29/11

Summary of content (1 pages)