User's Manual
Play Sound
The device supports using BASIC SET or SWITCH_MULTILEVEL SET to
play the sound. The sound ID is define as follow:
1: Emergency sound.
2: Fire alert.
3: Ambulance sound.
4: Police car sound.
5: Door chime.
6~99: Beep Beep.
0: means stop the sound, but will check the priority.
And the 255 is a special one, if the node priority is 1 or 7, the device
will play the last sound.
The priority 2 will play emergency sound.
The priority 3 will play fire alert.
The priority 4 will play ambulance sound.
The priority 5 will play police car sound.
The priority 6 will play door chime.
Priority Specification
The association group 1 to 6, not only for report message and mapping
to the play sound. It also setting the priority number too. For instance
the node added in the group 3 and this node's priority number will be
3 too. And the node not find in any group, its priority will be 7. The
smaller priority number will have higher priority.
When the device is playing the sound ID 1, only the node with priority
1 or 2 can stop it or change playing another sound.
Playing sound ID 2, stop by priority 3,2,1.
Playing sound ID 3, stop by priority 4,3,2,1.
Playing sound ID 4, stop by priority 5,4,3,2,1.
Manual Battery Shutdown
When the DC power is dropped. The system will auto switch to use the
battery power. If you want to really shutdown the system, please follow
instructions as below.
1. Press and hold the circle button.
2. Click the tamper 3 times in 1.5 seconds.
3. Release the circle button.
4. If shutdown successful, the LED will flash 3 times.
After the battery shutdown, the system won't work anymore, unless the
DC power recovery.
Z-Wave Configuration Settings
Notice: The data size of the configuration settings is 1.
NO. Name Default
Valid
Values
Description
2 Alarm Duration 6 0~127
Play alarm sound duration, 1 tick is 30
seconds. Default is 3 minutes, maximum
is 63.5 minutes
0: means never auto stop.
Z-Wave Supported Command Class
COMMAND_CLASS_SWITCH_MULTILEVEL
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_VERSION
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
3