Installation Instructions

LED light will flash slowly.
Programming
2. Z-Wave’s Configuration
Configuration
Parameter
Function Size
(Byte)
Value Unit Default Description
1
Fixed timer for re-
port Co2 concen-
tration
1 0-127 1 Units of 1 minute.
2
Concentration
change report
1 0-100 10 Units of 1 %.
3
Baseline level 1
1 0-50 6 Units of 100 ppm.
4
Baseline level 2
1 0-50 8 Units of 100 ppm.
5
Baseline level 3
1 0-50 10 Units of 100 ppm.
6
Baseline level 4
1 0-50 12 Units of 100 ppm.
7
Baseline level 5
1 0-50 16 Units of 100 ppm.
2. Firmware update over the air (OTA)
PAT12 is based on 500 series SoC and supports Firmware Update Command
Class, it can receive updated firmware images sent by a controller via the Z-wave
RF media. It is a helpful and convenient way to improve functions, if needed.
Command Classes
The Sensor supports Command Classes including…
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_TRANSPORT_SERVICE_V2,
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_SECURITY_2,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_NOTIFICATION_V3,
COMMAND_CLASS_SECURITY,
COMMAND_CLASS_SENSOR_MULTILEVEL_V11,
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
Over The Air (OTA) Firmware Update
The device supports Z-Wave firmware update via OTA.
Before starting the update, please remove the front case of the device otherwise the
hardware check will fail.
Let the controller into firmware update mode, and press the front tamper key once to
start the update.
After firmware download is complete, the LED light will flash intermittently.
Overview
3