User Instructions

NO
.
Name Def. Valid Description
3 eCO2 Threshold
line 1
6 1 ~ 100
eCO2 difference return:
The Unit is 100ppm.
0 means turn off eCO2 detected function.
4
eCO2 Threshold
line 2
8 1 ~ 100
eCO2 difference return:
The Unit is 100ppm.
0 means turn off eCO2 detected function.
5
eCO2 Threshold
line 3
10 1 ~ 100
eCO2 difference return:
The Unit is 100ppm.
0 means turn off eCO2 detected function.
6
eCO2 Threshold
line 4
16 1 ~ 100
eCO2 difference return:
The Unit is 100ppm.
0 means turn off eCO2 detected function.
7
eCO2 Threshold
line 5
30 1 ~ 100
eCO2 difference return:
The Unit is 100ppm.
0 means turn off eCO2 detected function.
8
TVOC
Threshold line 1
1 1 ~ 100
TVOC difference return:
The Unit is 100ppb.
0 means turn off TVOC detected function.
9
TVOC
Threshold line 2
2 1 ~ 100
TVOC difference return:
The Unit is 100ppb.
0 means turn off TVOC detected function.
10
TVOC
Threshold line 3
6 1 ~ 100
TVOC difference return:
The Unit is 100ppb.
0 means turn off TVOC detected function.
11
TVOC
Threshold line 4
22 1 ~ 100
TVOC difference return:
The Unit is 100ppb.
0 means turn off TVOC detected function.
12
TVOC
Threshold line 5
55 1 ~ 100
TVOC difference return:
The Unit is 100ppb.
0 means turn off TVOC detected function.
13
(*)
Customer
Function
1 All Customer function switch, using bit
control.
Caution: The value is unsigned byte, the
NO
.
Name Def. Valid Description
range is from 0x00 ~ 0xFF.
1 Bit0: Tamper On/Off (1:On, 0:Off)
0 Bit1: Reserve.
0 Bit2: Reserve.
0 Bit3: Reserve.
0 Bit4: Reserve.
0 Bit5: Reserve.
0 Bit6: Reserve.
0 Bit7: Reserve.
14
ECO2 Auto
Report Time
1 0 ~ 127
The interval time for auto report the eCO2.
0 means turn off auto report battery.
The default value is 1. The tick time can
setting by the configuration No.16.
15
TVOC Auto
Report Time
1 0 ~ 127
The interval time for auto report the
TVOC.
0 means turn off auto report illumination.
The default value is 1. The tick time can
setting by the configuration No.16.
16
Auto Report
Tick Interval
3 0 ~ 0xFF
The interval time for auto report each tick.
Setting this configuration will effect
configuration No.14 and No.15.
The unit is 1 minute.
Caution1: Setting to 0 means turn off all
auto report function.
Caution2: The value is unsigned byte, the
range is from 0x00 ~ 0xFF.
17 eCO2 10 1~100% The eCO2 Differential to report.
4