User Instructions
2. Pressing tamper key three times within 2 seconds to enter the
inclusion mode.
3.
After add successful, the device will wake to receive the
setting command from Z-Wave
TM
Controller about 20
seconds.
Remove
(Exclusion)
1.
Have Z-Wave
TM
Controller entered exclusion mode.
2. Pressing tamper key three times within 2 seconds to enter the
exclusion mode.
Node ID has been excluded.
Reset
1. Pressing Include button of PAT05 three times within 2
seconds will enter inclusion mode.
2. Within 1 second, press Include button of PAT05 again for 5
seconds.
SmartStart
1. Product has a DSK string, you can key in first five digit to
increment smart start process, or you can scan QR code.
2. SmartStart enabled products can be added into a Z-Wave
network by scanning the Z-Wave QR Code present on the
product with a controller providing SmartStart inclusion. No
further action is required and the SmartStart product will be
added automatically within 10 minutes of being switched on in
the network vicinity.
Association
1. The PAT05 is an always listening Z-Wave device, so
associations may be added or removed by a controller at any
time. Or If your controller requires to have the PAT05 send a
'node information frame' or NIF for associations, then
pressing the On/Off button three times within 2 seconds will
cause the PAT05 to send its NIF.
Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a
node ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-
Wave Controller.
Z-Wave
TM
Message Report
* eCO2 Report:
When the eCO2 detected state changed, the device will unsolicited to send the
“Sensor Multilevel Report” to the nodes in the group 1.
Sensor Type: eCO2 (0x11)
*** eCO2 Differential percent Report***
This function default is enabled, to disable this function by setting the configuration
NO.17 to 0.
In the default, when the eCO2 is changed to percentage, the device will report eCO2
information to the nodes in the group 1.
Caution 1: If the configuration No.3, No.4, No.5, No.6 and No.7 is setting to 0 this
functionality is useless.
* TVOC Report:
When the TVOC detected state changed, the device will unsolicited to send the
“Sensor Multilevel Report” to the nodes in the group 1.
Sensor Type: TVOC (0x27)
*** TVOC Differential percent Report ***
This function default is enabled, to disable this function by setting the configuration
NO.18 to 0.
In the default, when the TVOC is changed to percentage, the device will report TVOC
information to the nodes in the group 1.
Caution 1: If the configuration No.8, No.9, No.10, No.11 and No.12 is setting to 0 or
100, this functionality is useless.
2