User's Manual

Troubleshooting
Symptom Cause of Failure Recommendation
The dimmer does not
work and LED off
1.The dimmer does not
connect the electrical
wire properly
2.The dimmer break down
1. Check power connections
2. Don’t open up the dimmer and send it for
repair.
The dimmer LED
illuminating, but cannot
control the ON/OFF
state of the load
attached
Check if the load
connected to the dimmer
has its own ON/OFF
switch
Set the ON/OFF switch of the load attached
to ON
The dimmer LED
illuminating, but the
Detector cannot control
the Switch
1. Not carry out
association
2. Same frequency
interference
1. Carry out association
2. Wait for a while to re-try
Specification
Input Rating:(Operating Voltage) 100~240Vac / 50Hz~60Hz
Input Rating:(Operating Current) 0.01~1A ; (Maximum: 1A)
Output Rating: Maximum Load (Current) Maximum: 0.9A (100~240Vac)
Output Rating: Maximum Load (watts)
(230V)
200W (13W x 15 pieces) (Dimmable LED bulbs)
(230Vac)
Output Rating: Maximum Load (watts)
(120V)
100W (13W x 15 pieces) (Dimmable LED bulbs)
(120Vac)
Output Rating: Maximum Dimmable LED
bulbs
Maximum: 15 pieces (Dimmable LED bulbs)
Operating Temperature 0°C ~ 40°C
Frequency Range 868.40MHz & 869.85MHz/ EU (PAD07-EU);
908.4MHz & 916.0MHz/ USA (PAD07-US);
RF Maximum Power +5dBm
Transmission Range Minimum 40 m in door 100m outdoor line of sight
Modulation Type FSK (Frequency-Shift Keying)
** Specifications are subject to change and improvement without notice.
FCC ID : RHHPAD07
6