User's Manual

3 External switch
type
1 1-3 1 1 : One switch mode
2 : Two switch mode
3: Up/Down switch
mode
4 Restore dimmer
state
1 0-2 1 0 : Dimmer off
1 : Last dimmer state
2 : Dimmer on
3-1 Dimmer level report mode :
Whenever dimmer on/off state changes, it will send MULTILEVEL_SWITCH_
REPORT to the nodes of group1. The default setting is Enable the function.
3-2 LED indication mode :
3-2-1 Show dimmer State
When dimmer is on, LED is on. When dimmer is off,
LED is off. The default setting is Show dimmer State.
3-2-2 Show Night mode
When dimmer is on, LED is off. When dimmer is off,
LED is on.
3-2-3 One flash mode
When dimmer on/off state changes, LED will light on one
second and then off.
3-3 External switch type
3-3-1 One switch mode
Only S1 can dim up the light bulb to brightest level, then
dim down to darkest level, and so on…
3-3-2 Two switch mode
S1 and S2 can dim up the light bulb to brightest level,
then dim down to darkest level, and so on…
3-3-3 Up/Down switch mode
S1 can only dim up the light bulb to brightest level,
and S2 can only dim down to Off.
3-4 restore dimmer state :
Whenever the AC power return from lost, PAD07 will restore the switch state which
could be Dimmer offLast dimmer stateDimmer on. The default setting is Last dim-
mer state.
4. Firmware update over the air (OTA)
PAD07 is based on 500 series SoC and supports Firmware Update Command
Class, it can receives the updated firmware image sent by controller via the Z-
wave RF media. It is a helpful and convenient way to improve some function if
needed.
5. Command Classes
The Switch supports Command Classes including…
* COMMAND_CLASS_ZWAVEPLUS_INFO
* COMMAND_CLASS_VERSION_V2
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
* COMMAND_CLASS_SECURITY
* COMMAND_CLASS_DEVICE_RESET_LOCALLY
* COMMAND_CLASS_ASSOCIATION_V2
* COMMAND_CLASS_ASSOCIATION_GRP_INFO
* COMMAND_CLASS_POWERLEVEL
* COMMAND_CLASS_BASIC
* COMMAND_CLASS_SWITCH_MULTILEVEL_V2
* COMMAND_CLASS_CONFIGURATION
* COMMAND_CLASS_ALARM
* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
* COMMAND_CLASS_SCENE_ACTIVATION
* COMMAND_CLASS_SCENE_ACTUATOR_CONF