User's Manual

1-2 BASIC_SET / MULTILEVEL_SWITCH _SET
Upon receipt of the following commands from a Z-Wave Controller, the load
attached to the dimmer will turn on or off.
[Command Class Basic, Basic Set, Value = 0] : the load attached to the
dimmer turns off.
[Command Class Basic, Basic Set, Value = 1~99] : the attached load dim on as
the level.
[Command Class Multilevel Switch, Multilevel Switch Set, Value=0, Duration =
0~255] : the load attached to the dimmer turns off.
[Command Class Multilevel Switch, Multilevel Switch Set, Value =1~99, Dura-
tion = 0~255] : the attached load dim on as the level.
1. Z-Wave’s Groups (Maximum 5 nodes)
The Switch can be set to send reports to associated Z-Wave devices. It supports
one association group with five nodes support for grouping 1. For group 1, the dim-
mer
will report MULTILEVEL_SWITCH_REPORT, ALARM_REPORT and DEVICE_RE-
SET_LOCALLY_NOTIFICATION.
2-1 Auto report to Grouping 1
2-1-1 On/Off Event Report
When “on” or “off ” state has been changed, it will send Multilevel Switch Report to
the
nodes of Grouping 1.
Multilevel
Switch Report
ON:[Command Class Multilevel Switch, Multilevel Switch Report, Value
=1~99]
OFF:[Command Class Multilevel Switch, Multilevel Switch Report, Value
=0(0x00)]
2-1-2 Overload alarm report
When PAD07 detects the Overload, it will send Alarm Report to Group 1 nodes. After
detecting overload state and sending this alarm report, PAD07 will turn off the dim-
mer automatically and lockout the On/Off button and S1/S2. The only thing to do is
unplug PAD07 and reduce the load. Then re-power on PAD07 and it will work again.
The content of Alarm Report
Alarm report command: [Command_Class_Alarm, Alarm_Report, Alarm Type =
0x08, Alarm Level = 0xFF]
2-2 Send Basic Set to Grouping 1
When “on” or “off ” state has been changed by manual key pressing, a Basic Set
command will follow the Multilevel Switch Report send to the nodes of Grouping 1.
[Command Class Basic, Basic Set, Value = 0]
[Command Class Basic, Basic Set, Value = 1~99]
3.
Z-Wave’s Configuration
Configuration
Parameter
Function Size
(Byte)
Value Unit Default Description
1 Dimmer Level
Report mode
1 0-1 1 0 : Disable
1 : Enable
2 LED indication
mode
1 1-3 1 1: Show dimmer state
2 : Show night mode
3: One flash mode
4