User's Manual
(Bit Address+Destination End Point = 0x05) (Bit Address =0
;
Destination End Point =
command owner Endpoint value)
Command Class = 0x32 (Command_Class_Meter_V3 = 0x32)
Command =0x02 (Meter_Report = 0x02)
Parameter 1 = 0x21 (Scale Bit2 = 0
,
Rate Type = 0x01
,
Meter Type=0x01)
Parameter 2 = 0x44 (Precision = 2
,
Scale Bit1Bit0 = 0
,
Size
= 4)
Parameter 3 = 0x00 Accumulated Power Consumption =
0x000005FD = 15.33 KWh
Parameter 4 = 0x00
Parameter 5 = 0x05
Parameter 6 = 0xFD
2-3-5-2 Get Instant Power Consumption (Watt) from endpoint
METER_GET example
:
COMMAND_CLASS_MULTI_CHANNEL
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x05 (this is the endpoint of command owner,
here we assume endpoint is 5
,
if the owner
doesn’t support multi Channel this value will
be 0)
(Bit Address+Destination End Point =
0x03)
(Bit Address =0
;
Destination End Point
range 1~3)
Command Class = 0x32 ( Command_Class_Meter_V3 = 0x32)
Command =0x01 (Meter_Get = 0x01)
Parameter 1 = 0x10 (Scale = W = 0x02)
PAB01 Instant Power Consumption (W) Report example
:
COMMAND_CLASS_MULTI_CHANNEL
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03 (Meter report = Endpoint3)
(Bit Address+Destination End Point = 0x05) (Bit Address =0
;
Destination End Point =
command owner Endpoint value)
Command Class = 0x32 (Command_Class_Meter_V3 = 0x32)
Command =0x02 (Meter_Report = 0x02)
Parameter 1 = 0x21 (Scale Bit2 = 0
,
Rate Type = 0x01
,
Meter Type=0x01)
Parameter 2 = 0x34 (Precision = 1
,
Scale Bit1Bit0 =
0x02
,
Size = 4)
Parameter 3 = 0x00