User's Manual
Programming
,
1. Z-Wave’s Groups (Association Command Class Version 2)
The meter can be set to send reports to associated Z-Wave devices. It supports 3
association groups which every group has one node support. Group1~Group3
support METER_REPORT_COMMAND_V3
For group 1, the Switch will report (1) The sum of instant Power Consumption (Watt)
read from CT1 and CT2 (2) The sum of accumulated Power Consumption (KWh)
read from CT1 and CT2.
For group 2, the Switch will report (1) Instant Power Consumption (Watt) read from
CT1 (2) Accumulated Power Consumption (KWh) read from CT1.
For group 3, the Switch will report (1) Instant Power Consumption (Watt) read from
CT2 (2) Accumulated Power Consumption (KWh) read from CT2.
2-1 Auto report to Grouping 1 ~3 (Maximum Node 1 per Group)
2-1-1 Instant Power Consumption vary over 5% report
When the instant power consumption read from CT1 or CT2 vary over 5%, it will
send Meter report to the nodes of Group
2-2 Response to Meter Get Command
The Switch will report its (1) instant Power Consumption (Watt) or (2) accumulated
power consumption(KWH) or (3)
AC input Voltage (V) or (4)
AC load current ( I )
(5)
load power factor (PF) to Z-Wave Controller after receive the Meter Get
Command from Z-Wave Controller.
2-2-1 Instant Power Consumption (Watt)
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)]
Meter Report Command: [Command Class Meter
,
Meter Report
,
scale(bit
2) +Rate Type +Meter Type
,
Precision + Scale(bit 1,0)+ Size
,
Meter
Value 1
,
Meter Value 2
,
Meter Value 3
,
Meter Value 4]
Rate Type = 0x01
Meter Type = 0x01
Precision = 1
Scale = 0x02(W)
Meter Report Command: [Command Class Meter,Meter
Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit
1,0)+ Size,Meter Value 1,Meter Value 2,Meter Value 3,
Meter Value
4]