User's Manual

Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node
ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Controller.
LED Indication
To distinguish what mode the meter is in, view from the LED for identification.
State Type LED Indication
No node ID Under normal operation, when the meter has not been allocated a
node ID, the LED flashes on and off alternately at 2 seconds
intervals.
Learning When PAB01 is in learning mode, LED flashes on and off
alternately and repeatedly at 0.5 second intervals.
Choosing a Suitable Location
1. Do not locate the meter facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Switch is 0°C~40°C.
3. Do not locate the meter where exists combustible substances or any source of
heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of meter will become a little bit hot of which
phenomenon is normal.
Installation
1. Put the in wall switch into a wall box and connect the AC power wire L,N to
PAB01 connector L, N.
2. The black wire of current sensor, CT1 or CT2, should connected to the negative
terminal of PAB01,CT1- or CT2-. Another wire should connected to the plus
terminal of PAB01,CT1+ or CT1+.
3. There is a clasp on the side of the current sensor, it can lock or unlock the clamp.
It is convenient to circle the already connected cable.