Data Sheet

POE29U-1AF-R Characteristics
WWW.PHIHONG.COM
INPUT:
AC Input Voltage Rating
100 to 240VAC
AC Input Voltage Range
90 to 264VAC
AC Input Current
0.8A (RMS) maximum at 120VAC
0.55A (RMS) maximum at 240VAC
AC Input Frequency
47 to 63Hz
Leakage Current
350uA maximum for U models
250uA maximum for W models
Max In-rush Current
60A maximum at 240VAC and maximum
load (Cold Start at ambient 25°C)
OUTPUT:
Output Power
20W
Hold up Time
10mSec minimum at maximum load at
120VAC, 60Hz
Transient O/P Voltage Protection
60V maximum at switch on/off at any AC
line phase
Efficiency
80% Typical at maximum load at 120VAC,
60Hz
ENVIRONMENTAL
Temperature
Operation -20 to +50°C
Non-operating -20 to +70°C
Humidity 5 to 90%
EMI
Complies with FCC Class B
Complies with EN55032 Class B
EMC
ESD: IEC61000-4-2 Level 3
RS: IEC61000-4-3 Level 3
EFT/Burst: IEC61000-4-4 Level 2
Surge: IEC61000-4-5 Level 3
CS: IEC61000-4-6 Level 3
Voltage Dips: IEC61000-4-11
Harmonic: IEC61000-3-2 Class A
Isolation (HI-POT)
Primary to secondary: 1500VAC for 1
minute, 10mA
Insulation Resistance
Primary to secondary: 10M Ohm 500VDC
FEATURES:
Over Voltage/Current, Short Circuit
Protection
The output can be shorted permanently
without damage.
Indicators
Solid Green: Valid IEEE802.3af load
detected and connected “ON”
Blinking Green: Power “ON” ready for
connection
Blinking Green/Red: Invalid load connected
Blinking Red/Green: fault
AC Input Connector
IEC320 C14 – three wire
Output Connection
+pins 3,6 / -pins 1,2
Data IN/POE OUT Connector
RJ45