User Manual
MODEL NO.
AG2412-E281
SHEET NO
8
ISSUED DATE:
JUL/06/2007
DESCRIPTION SWITCHING MODE
AC ADAPTER
REVISED DATE:
6.1.1 Ambient temperature: -25℃ ~ +85℃
6.1.2 Relative Humidity: 10% ~ 95%
6.2 Operation
The power supply shall be capable of operating continuously in any mode without
performance deterioration in the following environmental conditions:
6.2.1 Ambient Temperature: 0℃ ~ 40℃
6.2.2 Relative Humidity: 10% ~95%.
7.0 EMI EMISSIONS
The power supply meets the radiated and conducted emission requirements for a
CISPR22(EN55022) class B
8.0 SAFETY
The power supply must be certified or meet of the following safety standards:
Certified Meet
TUV-GS
★
CE
★
8.1 Dielectric Strength (Hi-Pot) Test System:
Withstand AC 3 K V/10mA, for 2 sec./ min., primary to secondary.
8.2 Insulation Resistance:
Primary to secondary: 10 M OHM
at 500 VDC .
8.3 Leakage current: ≦ 0.25mA
9.0 ENVIROMENTAL PROTECTION
9.1 RoHS and WEEE
This product from design to production all the parts and process should meet the
requirement of Restriction of the use of certain hazardous substances in electrical
and electronic equipment RoHS directive 2002/95/EC and also meet the directive
2002/96/EC of Waste electrical and electronic equipment (WEEE) .
9.2 EPA/CEC/MEPS regulation
To meet the energy saving trend, this product has designed to meet the American
EPA energy star program for the EPS regulation , or requirement of CEC
400-2006-002, AS/NZS/4665.2.2005 for Australia and New Zealand.
10.0 PACKAGING:
PE Bag .