User Manual

MODEL NO.
AG2412-E281
SHEET NO
7
ISSUED DATE:
JUL/06/2007
DESCRIPTION SWITCHING MODE
AC ADAPTER
REVISED DATE:
4.0 MECHANICAL
Introduction
The power supply will provide
Output power connector show as in
Table 4.1
FRONT VIEW OF OUTPUT CONNECTOR
Table 4.1 Pin out for DC Connector
PIN # Output Voltage
4.2 General Requirements
The power supply must not exceed an audible noise level of 32 dB while
operating under any combination of specified load and input voltages and
frequencies. This noise level shall be measured according to IEC standards
651 type 1, with the sound level meter pointed directly at the power supply in
a free-field condition, at a distance of 1 meter and by selecting nominal “A”
weighting frequency attenuation.
4.3 Power Supply Dimensions
The dimensions of the power supply are shown : (75x 34.5x55 m/m)
4.4 Input / Output Connection
AC PLUG EU 2PIN
DC OUTPUT
2468 20# 2.1X5.5X9.5mm 180Tuning fork +Kink 6FT
4.5Unit Color: BLACK
5.0 RELIABILITY
5.1 Reliability
The design and construction of this power supply shall exhibit a minimum mean
time between failure of 50,000 hours full rated load operation at 25.0,
According to the MIL-HDBK-217F.
5.2 Burn-in
The power supply will be performed 100% burn-in at 405℃) under
80%-100% of full load on all power supplies.
6.0 ENVIRONMENT
6.1 Storage
The power supply shall be capable of withstanding the following environmental
conditions for extended periods of time, without sustaining electrical and/or
mechanical damage and subsequent operational deficiencies: