User Manual
MODEL NO.
AG2412-E281
SHEET NO
6
ISSUED DATE:
JUL/06/2007
DESCRIPTION SWITCHING MODE
AC ADAPTER
REVISED DATE:
shown below when measured under constant load range of 0.01 ~2A
with an oscilloscope with at bandwidth of 20MHz.
TABLE 2.2.5
Output # Voltage Maximum peak to peak ripple and noise
1 +12V 120 mV
NOTE: Test measurement will be made at the output connector on the power
Supply output cord. With used an aluminum Electrolytic capacitor of 10uf and
ceramic of 0.1uf parallel on output terminal can prevent unknown noise pick up.
2.3 Transient Response and Deviation
The load regulation for +12V is less than +/-10% while the measuring is down by
changing the measured output loading from +20% to +80% of rated load .
2.4 Turn on, Hold up Time
During turn on and turn off, no voltage shall exceed its nominal voltage by more
than 10% and no output will change its polarity with respect to its return line. All
outputs shall reach their steady state values within 2 seconds of turn on and the
hold up time for the output must be at least 10 mS tested at 110VAC/50HZ input
with 80% maximum load on output.
2.5 Efficiency
The efficiency (watt out/watt in) shall be a minimum of 78.6 % under line
input 115Vac/60Hz and full load.
3.0 PROTECTION
3.1 Input Current
An input fuse with a rating of 2A/250V Amps, shall be provided to protect the
power supply and the input wiring. Note: The fuse shall be an unchangeable unit.
3.2 Output Voltage (OVP)
The power supply shall shut down all outputs when any output voltage reaches to
it’s over voltage protection trigger point. ( Maximum=130% output voltage)
Note: This is not a repeatable test, when it triggers it is a perennial shut down.
3.3 Output Current (OCP)
Overload conditions shall cause both the output current and the output voltages to
decrease. Removal of an output overload conditions shall permit automatic
recovery of the output voltage. The over current protection point Maximum=300%
for all outputs . Note : The total output power should not over Rated power to
operate ,otherwise will caused the power supply to damage.
3.4 Short Circuit Protection (SCP)
The power supply shall be protected from damage of accidentally short on the
output terminal.