User Manual
MODEL NO.
AG2412-E281
SHEET NO
5
ISSUED DATE:
JUL/06/2007
DESCRIPTION SWITCHING MODE
AC ADAPTER
REVISED DATE:
INTRODUCTION
This documents specifies ONE voltage +12V power supply for electronic data
processing equipment. The power supply will provide power to all system components.
1.0 INPUT REQUIREMENTS
1.1 Input Voltage Designing Range: 90~264 VAC.
1.2 Line Frequency Designing Range: 47 HZ to 63 HZ.
1.3 In-Rush Current: 30 A max. less under 115V conditions.
Interruption of the input voltage for duration sufficient to cause the output voltage
to drop below the regulation setting shall cause reactivation of in rush limiting
capability. ( Full-load 25℃ Cold-start )
1.4 Input Current: 0.5 A max. at any line voltage specified in 2.1 at output full load
condition.
2.0 OUTPUT REQUIREMENTS
2.1Output Power (Rated Power)
The unit total output power from all voltage under steady state condition will
not exceed 24W watts
2.2Output Regulation
Label Information per Safety Agencies according to UL1950 and or EN60950
Requirements.
2.2.1 Input Rated Voltage Range: 100~240 VAC.
2.2.2 Line Rated Frequency: 50 HZ to 60 HZ.
2.2.3 Static Load
TABLE 2.2.3
Output
Voltage Minimum Load Maximum Load Surge Current
1 +12V 0A 2A ------
2.2.4Output Voltage
The output voltage shall be statically regulated for all combinations of
load (min./ max.), line and environment, including cross regulation (if
any)as shown:
TABLE 2.2.4
Output # Voltage Range Tolerance
1 +12V +11.4V~+12.6V
-5%,+5%
NOTE: Test measurement will be made at the output connector on the power
Supply output cord and well connected on the mating connector.
2.2.5 Ripple and Noise
Differential ripple and noise at the power supply output shall be as