User Guide

19
2.8 Attaching the IQ1 Back
The IQ1 back is fully integrated with the camera body and functions as a part
of the whole camera system.
Ensure that the Phase One 645DF+ camera mirror is up and the shutter is
open when no digital back is attached.
When attaching the IQ1 back to the camera body the shutter will close and
the mirror come down.
First remove the cover. Next, ensure that the bottom part of the IQ1 back is
placed correctly in the lower locking mechanism on the back of the camera
body before the upper locking mechanism [A+B] is pressed together. Failure
to do this can cause an error with the camera body where the shutter will
continuously open and close. If this occurs, remove the IQ1 back. Make sure the
camera body is powered, press button [2] while mounting the digital back,
lock the mounted back by pressing [1].
Please be aware that the shutter should be in the correct starting position
(shutter open). If this is not the case, attach and remove the IQ1 back again to
make sure that the camera body gets in the correct starting position.
Remove the IQ1 back by sliding the back lever [1], pushing in button [2], and
by gently pulling away the top of the back rst. Be careful with the contacts
and protective glass on the back. Your IQ1 back should always be protected
by its plate when it is not attached to the camera.