User Manual
Page 19 of 28
Document Reference Phalcon NT, Issue 9 and Date 07/04/2020
THIS IS THE PROPERTY OF PHAROS MARINE AUTOMATIC POWER LIMITED. DISCLOSURE OR REPRODUCTION IS FORBIDDEN
UNLESS AUTHORISED
The Power Connector on the Transponder is defined and configured as shown below. A suitable mating connector
with appropriate sealing should be used in the construction of the power cable.
Transponder’s Power Connector: Amphenol 62GB-12E14-19PN
19 Way cable connector cores with optional 4 CORE CABLE
Function Signal
19-Way Metal
Circular Bulkhead
Connector
POWER
BITE
19 Way cable
connector cores
With optional 4 core
cable
BITE On - Normally Close Relay Contact (Open if Fault A High) A
BITE Middle - Relay Contact M
3
BITE Off - Normally Open Relay Contact (Closed if Fault A High) L
4
BITE Fault Ref B
BITE Neg Fail - Opto Pulled to Fault Ref when Fault A High C
POWER +V J
1
POWER +V H
POWER +V G
POWER 0V K
2
POWER 0V T
POWER 0V S
BITE Relay Enable A (Link to Relay Enable B to enable relay) D
BITE Relay Enable B (Link to Relay Enable A to enable relay) E