User Manual

Page 10 of 28
Document Reference Phalcon NT, Issue 9 and Date 07/04/2020
THIS IS THE PROPERTY OF PHAROS MARINE AUTOMATIC POWER LIMITED. DISCLOSURE OR REPRODUCTION IS FORBIDDEN
UNLESS AUTHORISED
Interfaces
External interface
+10V to +36V DC (operating – 10% Tx duty cycle) < 10 W
+10V to +36V DC (standby) <0.1W
Current 3A max
Power
Connector types – MIL-C-
38999 . See appendix B
Control Interface
Monitor and Control (M&C) and in field programming
RS 232
Connector types – MIL-C-
38999 . See appendix B
Mechanical
Height 810mm nom
Diameter (including lift ring) 384mm nom
Weight (Transponder with standard base ring) 10.5kg
Housing Plastic Moulding
Submersion Capability (Survival - Non operating) 2m min.
Lifting
2 painted metal handles
attached to mid section