User Manual

Page 53 of 57
Document Reference Phalcon-NT11, Issue 2 and Date 24/10/18
THIS IS THE PROPERTY OF Pharos Marine Automatic Power. DISCLOSURE OR REPRODUCTION IS FORBIDDEN UNLESS AUTHORISED
Registered Address: 14 Castle Mews, Hampton, England, TW12 2NP Company Reg. No. 06757705 VAT Reg. No. GB222645483
R1
None
1.15.5 Example
Figure 19 Example Sets Sleep mode to 7s Sleep,10s Sleep (no traffic) and 8s (traffic present) RX, 300 minimum Pulses counted during the
listen period for full wake up from sleep mode.
1.16 Stop the transponder running “STOP”
1.16.1 Description
During configuration of the system it is advised that the system is stopped. This stops the transponder outputs to the
console and allows the user to easily type commands. When completed the user can run the system using the “RUN”
command.
The system will only stop after its cycle has been completed. Stop can also be applied after a reset or power cycle at
the command prompt. The user has approximately 10 seconds before the system automatically runs.