1.13.4 Example
ELMO>>RUN
OK
ELMO>>
RADARGO RUNNING
RADARGO SELF TEST: PASS
RADARGO SYSTEM ALARM - CLEAR
RADARGO CONSOLE Awake 5s for commands:
BATTERY GOOD 281
RADARGO SLEEP RX 4s PULSES 0
þ†øÆ..
RADARGO SELF CAL COMPLETED
RADARGO SYSTEM LIVE RUNNING
RADARGO PROCESS 0 RADARS, COMPLETED
RADARGO SYSTEM POWER DOWN
SYSLOG SLEEP CYCLES : 0
SYSLOG WAKE UP CYCLES : 1
SYSLOG SLEEP AFTER CYCLE : 0
SYSLOG TOTAL CYCLES : 1
SYSLOG X BAND ATTEMPTS : 18
SYSLOG X BAND RESPONSES : 18
SYSLOG S BAND ATTEMPTS : 60
SYSLOG S BAND RESPONSES : 59
SYSLOG HOURS ALIVE : 0
SYSLOG ALARMS : 0x0
Figure 18 Example run command and output
1.14 Save Configuration “SAVE”
1.14.1 Description
Save user configuration into the configuration memory. Ensure that the unit is connected to a stable power supply
before “SAVE” is applied.
If the unit power should fail during programming of the configuration memory, it is likely that the memory will
become corrupted. When the unit powers back up the unit will attempt to recover the configuration from backup
memory and restore these to the main transponder configuration which was set before the programming failure. If
this happens the user should verify their settings using ‘CFGGET’ and re-apply and save if required.
Should both the backup and the main configuration image be corrupt the unit will stop, an alarm will be raised and
the following message displayed during the bootup on the console; Main Config and Backup are corrupted, System
Stopped. If the configuration memory becomes corrupted during ‘normal’ operation then normal operation may
cease the user may observe this affecting the output and operating conditions.
The reason for both images to become corrupted should be investigated further. It could be possible depending on
the situation to recover the unit in this condition by applying a factory reset. However key configuration could be
changed during this process depending on how the unit was configured in the factory. Further configuration could be
required.