1.11.3 Command and Parameters
Command RLOG
Parameter Title Type Min Max Description
P1 None
1.11.4 Command Return
Command RLOG
Parameter
Title Type Min Max Description
R1 SLEEP CYCLES UINT32 0 4294967295
Number of times the
system has gone into sleep
R2
WAKE UP CYCLES
UINT32
0
4294967295
Number of times the
system has woke up from
RX Pulses and started a
system RX.
R3
X BAND ATTEMPTS
UINT32
0
4294967295
Number of attempts to
output a response.
R4 X BAND RESPONSES UINT32 0 4294967295
Number of successful out
responses. (Success is the
system responding to 1 or
more radar pulses)
R5 S BAND ATTEMPTS UINT32 0 4294967295
Number of attempts to
output a response.
R6 S BAND RESPONSES UINT32 0 4294967295
Number of successful out
responses. (Success is the
system responding to 1 or
more radar pulses)
R7 HOURS ALIVE UINT32 0 4294967295
Hours system has been
powered and running.
R8
ALARMS
UINT16
0
0xFFFF
Hex Output.